Scale a raw signal into engineering units
Turn a raw reading, like volts or counts, into the unit you work in, like
bar or N. You check it against the live value before you save.
Before you start
- An input that is running, so its channels have live readings.
- The numbers that convert the reading: a slope and offset, a sensitivity, two known points, polynomial coefficients, or a certificate table.
Steps
Open Inputs and click the input's row. Its channels are listed under it.
Click a channel, then press Edit calibration. Some connectors keep calibration on their own page; the button then reads Calibrate on the … connector and opens it.
Under Scaling, pick a type and fill in its numbers:
Type Fill in Linear · y = a·x + bslope & offset, a sensitivity from the sensor's certificate, or two points (what the channel reads → what it really is) Polynomial Coefficients, low order first: y = c0 + c1·x + c2·x² + …Table Points, raw → engineering; straight lines join them. Add row, or paste two columns Thermocouple type K, from volts. Offered only when the channel reads volts Formula an expression over this reading and other named channels, like (x - bias) / gainUnder Becomes, type the unit the reading turns into, like
bar. The raw unit is filled in for you.Optional: add a Label, like
PT-100 shunt, cert 2026-114.Watch Live now at the bottom. It shows
raw … → …with your draft applied to the live reading.Press Save calibration.
Share one calibration across channels
Under Also apply to, tick other channels that should use the same calibration. Each shows what it would read. Edit it once later, and every channel on it updates.
When you edit a shared calibration, Save it to asks whether to change all its channels or only this one.
Check it worked
The channel's row shows raw … → … in your unit, and Scaled by names the
calibration. On Live, the channel reads in the new unit.
| Also on the channel | Does |
|---|---|
| Zero | makes the channel read 0 at its current value, saved as a new record |
| History | lists earlier versions |
| Remove calibration | goes back to the raw value |
If an input's connector scales the value itself, the row says so. Use Move scaling into calibration rather than adding a second scale.